TAYLOR MORRISON/ARIZONA INC

HVAC
Plumbing
Remodel
Roofing
Primary market: Mesa, AZ
Records
21
Total declared value
$8,164,869
First seen
Jan 27, 2016
Last seen
Aug 4, 2016

Recent records

DateTypeAddressDescriptionValueContractorScore
Aug 4, 2016
permit
HVAC
3••• E FARGO STREMODEL PERMIT FOR THE GARAGE CONVERTING TO A CONSTRUCTION OFFICE. WORK SHALL INCLUDE NO STRUCTURAL OR PLUMBING CHANGES ONLY ADDING ADDITIONAL OUTLETS AND INSTALLING A FREE STANDING A/C UNIT. ALL ELECTRICAL WORK SHALL BE DONE PER NEC2005 STANDARDS. GARAGE AREAS MODIFIED OR IMPROVED FOR THE PURPOSE OF PROVIDING A TEMPORARY OFFICE SHALL BE RESTORED BACK TO A GARAGE PER PARKING STANDARDS IN CHAPTER Pro Pro48
Aug 4, 2016
permit
Remodel
3••• E FARGO STREMODEL PERMIT FOR THE GARAGE (REF NSFR BLD2016-04159) CONVERTING TO A SALES OFFICE FOR THE MODEL HOMES. GARAGE AREAS MODIFIED OR IMPROVED FOR THE PURPOSE OF PROVIDING A TEMPORARY OFFICE SHALL BE RESTORED BACK TO A GARAGE PER PARKING STANDARDS IN CHAPTER 32 OF ZONING ORDINANCE PRIOR TO THE SALE OR RESIDENTIAL OCCUPANCY OF SUCH MODEL HOME. SECURITY STANDARDS TO BE MET PER SEC R324. REF THE FOLLOWI Pro Pro48
Aug 3, 2016
permit
HVAC
1•••• E CORBIN AVETAYLOR MORRISON HOMES MASTER PLAN #4023 AT EASTMARK DU6 PARCEL 1.EXPEDITED - TAYLOR MORRISON HOMES MASTER PLAN #4073 AT EASTMARK DU6 PARCEL 1. 1957 SF SFR 1-STORY, 3-TANDEM CAR GARAGE; STD PLAN W/ 3 BEDROOMS, 3 BATHS, POST TENSION SLAB, GAS-ELECTRIC APPLIANCES AND AC/GAS FURNACE. WATER MAX DL=120 FT. METER SIZE=3/4, SUPPLY LINE=1"; GAS MAX.DL=1009 FT, TOTAL CFH=300. 200AMPS ELECTRICAL PANEL. Pro Pro58
Jul 29, 2016
permit
HVAC
3••• E FAIRFIELD ST1-STORY DETACHED SFR, 3839 SF LIVABLE SPACE, W/4 ELEVATIONS AVAILABLE: SPANISH, TUSCAN, PRAIRIE AND COTTAGE. ELECTRICAL & GAS APPLIANCES, POST TENSION SLAB, STUCCO SYSTEM W/ 1" CONTINUOUS RIGID FOAM INSULATION ON EXTERIOR WALL (R-4), O/2X6 FRAME WITH R-19 BATT INSULATION. CONCRETE TILE (S-TYPE AND FLAT) ON PRE-ENGINEERED TRUSSES W/R-30 BLOWN-IN CELLULOSE (10" THICK) INSULATION. GAS WATER HEATER, Pro Pro64
Jul 7, 2016
permit
HVAC
3••• E FARGO ST1-STORY DETACHED SFR, 3839 SF LIVABLE SPACE, W/4 ELEVATIONS AVAILABLE: SPANISH, TUSCAN, PRAIRIE AND COTTAGE. ELECTRICAL & GAS APPLIANCES, POST TENSION SLAB, STUCCO SYSTEM W/ 1" CONTINUOUS RIGID FOAM INSULATION ON EXTERIOR WALL (R-4), O/2X6 FRAME WITH R-19 BATT INSULATION. CONCRETE TILE (S-TYPE AND FLAT) ON PRE-ENGINEERED TRUSSES W/R-30 BLOWN-IN CELLULOSE (10" THICK) INSULATION. GAS WATER HEATER, Pro Pro64
Jul 7, 2016
permit
HVAC
3••• E FARGO ST1-STORY DETACHED SFR, 4083 SF LIVABLE SPACE. 4 ELEVATIONS STYLES, SAME SQ. FOOTAGE:SPANISH, TUSCAN , PRAIRIE, AND COTTAGE. ELECTRICAL & GAS APPLIANCES, POST TENSION SLAB, STUCCO SYSTEM WITH 1" RIGID CONTINUOUS INSULATION ON THE EXTERIOR FACE (R-4), O/2X6 FRAME WITH R-19 BATT INSULATION IN WALL CAVITY SPACE. CONCRETE TILE (S-TYPE AND FLAT) ON PRE-ENGINEERED TRUSSES W/10": OF BLOWN CELLULOSE (R-30 Pro Pro64
Jun 22, 2016
permit
Roofing
1•••• E LUMIERE AVEMASTER PLAN #E6001, EASTMARK DU7 PARCEL 6. LETTER OBTAINED FROM DMB.. SINGLE STORY FRAME BUILT SINGLE FAMILY RESIDENCE WITH STUCCO FINISH, CONCRETE TILE ROOF TILES OVER PRE-ENGINEERED WOOD ROOF TRUSSES. 3 CAR GARAGE, 3 BEDROOMS. FIRE SPRINKLERS ARE CONSIDERED AN ADDITIONAL OPTION PER MESA FIRE CODE 503.1.1. POST TENSION SLAB REQUIRES SPECIAL INSPECTION.FIRE SPRINKLERS ARE CONSIDERED AN ADDITIO Pro Pro65
Jun 22, 2016
permit
Roofing
1•••• E STEARN AVEMASTER PLAN #E6011, EASTMARK DU 7 PARCEL 6. LETTER OBTAINED FROM DMB.. SINGLE STORY FRAME BUILT SINGLE FAMILY RESIDENCE WITH STUCCO FINISH, CONCRETE TILE ROOF TILES OVER PRE-ENGINEERED WOOD ROOF TRUSSES. 3 CAR GARAGE, 3 BEDROOMS. FIRE SPRINKLERS ARE CONSIDERED AN ADDITIONAL OPTION PER MESA FIRE CODE 503.1.1. POST TENSION SLAB REQUIRES SPECIAL INSPECTION. Pro Pro65
May 25, 2016
permit
Roofing
1•••• E LUMIERE AVEMASTER PLAN #E6031, EASTMARK. LETTER OBTAINED FROM DMB.. SINGLE STORY FRAME BUILT SINGLE FAMILY RESIDENCE WITH STUCCO FINISH, CONCRETE TILE ROOF TILES OVER PRE-ENGINEERED WOOD ROOF TRUSSES. 3 CAR GARAGE, 4 BEDROOMS WITH 5TH OPTION. FIRE SPRINKLERS ARE CONSIDERED AN ADDITIONAL OPTION PER MESA FIRE CODE 503.1.1. HYDRALICS AND PLANS SUBMITTED WITH MASTER PLAN. POST TENSION SLAB REQUIRES SPECIAL Pro Pro66
Apr 26, 2016
permit
Plumbing
5••• S SELENIUM LNPLUMBING PERMIT FOR GAS PRESSURE TEST TO GET A GAS METER SET. REF PERMIT #BLD2013-01090. Pro Pro47
Unlock values, contractors, owner names & full addresses
Pro members see every field, export CSVs and set instant alerts.
Upgrade to Pro