DateTypeAddressDescriptionValueContractorScore
Aug 15, 2016
permit
Plumbing
7••• E OLLA AVEP.E. GAS LINE TO 400,000 BTU POOL HEATER, TO BE RUN 65' OF 1 1/2 ", P.E. GAS LINE TO 50,000 BTU BBQ, TO BE RUN 60' OF 3/4" ALL TO BE 18" UNDERGROUND, WITH 14 GAUGE TRACER WIRE & APPROVED TRANSITION RISER. UPGRADE GAS METER TO A ROTARY 8 C CLASS METER, TOTAL BTUS 755,000 Pro Pro47
Aug 15, 2016
permit
Plumbing
9••• E JUNE STP.E. GAS LINE FROM EXISITNG GAS STUB TO 50,000 BTU BBQ, TO BE RUN 72' OF 3/4" 18" UNDERGROUND, WITH 14 GAUGE TRACER WIRE & APPROVED TRANSITION RISER. COM GAS, NO METER UPGRADE NEEDED. Pro Pro47
Jul 26, 2016
permit
Plumbing
9••• E PLANA AVEREF POOL PERMIT #BLD2016-02822. P.E. GAS LINE TO 400,000 BTU POOL HEATER, TO BE RUN 95' OF 1 1/2" 18" UNDERGROUND, WITH 14 GAUGE TRACER WIRE & APPROVED TRANSITION RISER. SW GAS Pro Pro47
Jul 7, 2016
permit
Plumbing
3••• N PIEDRA CIRDESERT UPLANDS-BUILDINGE ENVELOPE LOT. INSTALL 3" POLYURETHANE GAS LINE 200LF TO POOL 400K BTU HEATER, 76 LF OF POLYURETHANE 1 1/2" GAS LINE TO (2) FIRE POTS 50K BTU EACH, 45 LF OF 1 1/2" POLYURETHANE PIPE TO 50K FIREPLACE, AND 19 LF OF 1 " POLYURETHANE GAS PIPE TO 100K BTU BBQ FOR A TOTAL DEVELOPED LENGTH OF 338 LF AND A TOTAL BTU OF 650,000. ADDED TO THE ORIGINAL GAS METER OF 865,000 BTU'S THE Pro Pro47
Jun 2, 2016
permit
Electrical
7••• E OSAGE AVEINSTALLATION OF 52' OF 1-1/2" PE GASLINE BURIED A MIN OF 18" WITH COPPER TRACER WIRE TO 400K BTU POOL HEATER, TO BE INSTALLED PER 2006 IFGC AND CITY OF MESA GAS REQUIREMENTS. COM GAS AREA TOTAL BTU'S = 570K UPGRADE TO 400 CLASS GAS METER. Pro Pro47
May 4, 2016
permit
Pool
6••• E MINTON PLINSTALLATION OF 10' OF 1" PE GASLINE BURIED 18" WITH COPPER TRACER WIRE FROM 120 GALLON PROPANE TANK TO 400K BTU POOL HEATER, TO BE INSTALLED PER 2006 IFGC AND FPD 3804.3. REF POOL PERMIT BLD2016-01731 Pro Pro46
Mar 1, 2016
permit
Electrical
7••• E OSAGE AVEINSTALLATION OF 45' OF 3/4" PE GASLINE BURIED 18" WITH COPPER TRACER WIRE TO 50K BTU BBQ FROM 3/4" EXISTING GAS STUB, TO BE INSTALLED PER 2006 IFGC AND CITY OF MESA GAS REQUIREMENTS. TOTAL BTU'S = 230K EXISTING 250 CLASS GAS METER OK. Pro Pro47
Jan 27, 2016
permit
Electrical
7••• E OSAGE AVEINSTALL 12' OF 3/4" PE GASLINE BURIED 18" WITH COPPER TRACER WIRE TO 50K BTU BBQ FROM EXISTING HOUSE STUB, TO BE INSTALLED PER 2006 IFGC AND CITY OF MESA GAS REQUIREMENTS. TOTAL BTU'S = 180K EXISTING 250 CLASS GAS METER OK. Pro Pro47